toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

EGR Valve|Testing and Inspection|Page 3027 > < EGR Temperature Sensor|Specifications|Page 3023
Page 1
background image

EGR Valve: Testing and Inspection

INSTALLATION HINT: Installation is in the reverse order of removal.

1. REMOVE EGR PIPE.

-

Remove the bolt, 4 nuts, EGR pipe and 2 gaskets. 

INSTALLATION HINT: Install 2 new gaskets.

Torque:
Bolt: 18 N.m (185 kgf.cm, 13 ft.lbf) 
Nut A: 19 N.m (195 kgf.cm, 14 ft.lbf) 
Nut B: 20 N.m (200 kgf.cm, 15 ft.lbf)
 

2. REMOVE EGR VALVE.

-

Disconnect these hoses:
(1) Vacuum hose
(2) EGR hose
(3) Water bypass hose (from IAC valve)
(4) Water bypass hose (from water bypass pipe)

-

Remove the 2 nuts, EGR valve and gasket.

Torque: 19 N.m (195 kgf.cm, 14 ft.lbf) 

3. INSPECT EGR VALVE.

-

Check for sticking and heavy carbon deposits.

-

If a problem is found, replace the EGR valve.

EGR Valve|Testing and Inspection|Page 3027 > < EGR Temperature Sensor|Specifications|Page 3023