Tacoma 4WD L4-164.4 2693cc 2.7L DOHC (3RZ-FE) (1996)
Vapor Pressure Sensor: Specifications
Output voltage with voltmeter connected to terminals PTNK and E2 of the ECM under the following conditions
Vacuum (2.0 kPa, 0.59 in Hg) applied .......................................................................................................................................................... 1.3 - 2.1 Volts
No vacuum .................................................................................................................................................................................................... 3.0 - 3.6 Volts
Pressure (1.5 kPa, 0.22 psi) applied .............................................................................................................................................................. 4.2 - 4.8 Volts