toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Generator (For Denso Made)|Page 5174 > < Generator (For Denso Made)|Page 5172
Page 2
background image

2. INSPECT STATOR SUB-ASSEMBLY GENERATOR WITH RECTIFIER

HINT:  For terminal positions of the stator generator, refer to the illustration.

a. Inspect the positive (+) rectifier.

HINT:  Inspect the positive terminal after pulling it up.

1. Using an ohmmeter, connect the positive (+) tester probe to the positive (+) terminal and the negative (-) tester probe to each rectifier

terminal.

2. Measure the resistance between the positive (+) terminal and rectifier terminal.

Standard: Below 1 Ohm 

If the result is not as specified, replace the stator generator.

3. Reverse the polarity of the tester probes and repeat step (1).
4. Measure the resistance between the positive (+) terminal and rectifier terminal.

Standard: 10 kOhms or higher

If the result is not as specified, replace the stator generator.

b. Inspect the negative (-) rectifier.

1. Using an ohmmeter, connect the positive (+) tester probe to each negative (-) terminal and the negative (-) tester prove to each rectifier

terminal.

2. Measure the resistance between the negative (-) terminal and rectifier terminal.

Standard: 10 kOhms or higher

Generator (For Denso Made)|Page 5174 > < Generator (For Denso Made)|Page 5172