toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

EGR Valve|Specifications|Page 3057 > < EGR Valve|Specifications
Page 1
background image

EGR Valve: Testing and Inspection

EGR VALVE INSPECTION 

Installation is in the reverse order of removal.

1. REMOVE EGR PIPE

Remove the bolt, 4 nuts, EGR pipe and 2 gaskets. 

INSTALLATION HINT:  Install 2 new gaskets.

Torque:

Bolt: 18 N.m (185 kgf.cm, 13 ft.lbf) 
Nut A: 19 N.m (195 kgf.cm, 14 ft.lbf) 
Nut B: 20 N.m (200 kgf.cm, 15 ft.lbf)
 

2. REMOVE EGR VALVE

(a) Disconnect these hoses:

(1) Vacuum hose
(2) EGR hose
(3) Water bypass hose (from IAC valve)
(4) Water bypass hose (from water bypass pipe)

(b) Remove the 2 nuts, EGR valve and gasket.

Torque: 19 N.m (195 kgf.cm, 14 ft.lbf) 

3. INSPECT EGR VALVE

Check for sticking and heavy carbon deposits. If a problem is found. replace the EGR valve.

EGR Valve|Specifications|Page 3057 > < EGR Valve|Specifications