Condenser HVAC: Service and Repair

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT:  At the time of installation, please refer to the following item.

Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)

2. REMOVE THESE PARTS:

a. Radiator grille
b. Horns
c. Hood lock set bolts
d. Center brace

3. REMOVE 2 LIQUID TUBES

a. Remove the 2 bolts and disconnect the liquid tubes from receiver

Torque: 6.0 Nm (60 kg.cm, 52 in.lb)

NOTE:  Cap the open fittings immediately to keep moisture or dirt out of the system.

HINT:  At the time of installation, please refer to the following item. Lubricate 2 new O-rings with compressor oil and install the tubes.

b. Loosen the 2 nuts and remove the 2 liquid tubes.

Torque: 14 Nm (140 kg.cm, 10 ft.lb)

NOTE:  Cap the open fittings immediately to keep moisture or dirt out of the system.

HINT:  At the time of installation, please refer to the following item. Lubricate 2 new O-rings with compressor oil and install the tubes.

4. DISCONNECT DISCHARGE HOSE FROM CONDENSER

a. Remove the piping clamp set bolt.

b. Remove the bolt and disconnect the hose.

Torque: 10 Nm (100 kg.cm, 7 ft.lb)

NOTE:  Cap the open fitting immediately to keep moisture or dirt out of the system.

HINT:  At the time of installation, please refer to the following item. Lubricate a new O-rings with compressor oil and install the tubes.

Condenser HVAC|Testing and Inspection|Page 4647 > < Condenser HVAC|Testing and Inspection