c. Check the valve lift.

Valve lift: 8.0 mm (0.31 inch) or more at 95°C (203°F) 
If the valve lift is not as specified, replace the thermostat.

d. Check that the valve is fully closed when the thermostat is at low temperatures (below 77°C (171°F)).

If not fully closed, replace the thermostat.

INSTALLATION 

1. INSTALL WATER INLET

a. Install a new gasket onto the water inlet with thermostat.
b. Install the water inlet with thermostat with the 3 nuts. 

Torque: 9.0 Nm (92 kgf-cm, 80 inch lbs.) 

2. CONNECT NO. 2 RADIATOR HOSE
3. CONNECT BATTERY NEGATIVE TERMINAL

Torque: 3.9 Nm (40 kgf-cm, 35 inch lbs.) 

4. ADD ENGINE COOLANT
5. CHECK FOR ENGINE COOLANT LEAKAGE
6. INSTALL V-BANK COVER

a. Install the V-bank cover with the 2 nuts. 

Torque: 7.5 Nm (76 kgf-cm, 66 inch lbs.)