3. Temperature control dial at "COOL" position

b. Adjust air inlet control cable.

Pull the mode control link at "FRESH" position, connect the control cable and lock the clamp.

HINT:  Lock the clamp during lightly pushing the outer cable in the direction, as shown in the illustration.

c. Adjust mode control cable.

Pull the mode control link at "FACE" position, connect the control cable and lock the clamp.

HINT:  Lock the clamp during lightly pushing the outer cable in the direction, as shown in the illustration.

d. Adjust air mix control cable.

Pull the air mix link at "COOL" position, connect the control cable and lock the clamp.

HINT:  Lock the clamp during lightly pushing the outer cable in the direction, as shown in the illustration.

e. Adjust water valve control cable.

Pull the water valve control lever at "COOL" position, connect the control cable and lock the clamp.

HINT:  Lock the clamp during lightly pushing the outer cable in the direction, as shown in the illustration.