toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Starter Motor|Locations|Page 5277 > < Starter Motor|Locations|Page 5275
Page 2
background image

1.4 kW type: 30 mm (1.18 in.)
2.0 kW
 type: 35 mm (1.38 in.)
Minimum diameter:
1.4 kW type: 29 mm (1.14 in.)
2.0 kW
 type: 34 mm (1.34 in.)
If the diameter is less than the minimum, replace the armature.

6. INSPECT UNDERCUT DEPTH

Check that the undercut depth is clean and free of foreign materials. Smooth out the edge.
Standard undercut depth:
1.4 kW type: 0.6 mm (0.024 in.)
2.0 kW
 type: 0.7 mm (0.028 in.)
Minimum undercut depth:
0.2 mm (0.008 in.)
If the undercut depth is less than the minimum, correct it with a hacksaw blade.

7. INSPECT FIELD COIL FOR OPEN CIRCUIT

Using an ohmmeter, check that there is continuity between the lead wire and field coil brush lead.
If there is no continuity, replace the field frame.

8. INSPECT FIELD COIL FOR GROUND

Using an ohmmeter, check that there is no continuity between the field coil end and field frame.
If there is continuity, repair or replace the field frame.