Instrument Panel Relay: Testing and Inspection

INSPECT BULB CHECK RELAY OPERATION

a. Connect the positive (+) lead from the battery to terminal C through a 1.4 W test bulb and the negative (-) lead to terminal B, check that the test

bulb does not light up.

b. Connect the positive (+) lead from the battery to terminal A and check that the test bulb lights up.

If operation is not as specified, replace the relay.