toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Starter Motor|Locations|Page 2846 > < Starter Motor|Locations|Page 2844
Page 4
background image

Standard Undercut Depth

Standard undercut depth:

Minimum undercut depth: 0.2 mm (0.008 in.)
If the undercut depth is less than minimum, correct it with a hacksaw blade.

3. INSPECT FIELD COIL

a. Check the field coil for open circuit.

Using an ohmmeter, check that there is continuity between the lead wire and field coil brush lead.
If there is no continuity, replace the field frame.

b. 1.4 kW:

Check the field coil for ground.
Using an ohmmeter, check that there is no continuity between the field coil end and field frame.
If there is continuity, repair or replace the field frame.

4. 2.0 kW:

INSPECT SHUNT COIL FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between terminal (A) and (B).
Standard resistance: 1.5 - 1.9 Ohm at 20°C (68°F)
If the resistance is not as specified, repair or replace the field frame.

5. INSPECT BRUSHES

Starter Motor|Locations|Page 2846 > < Starter Motor|Locations|Page 2844