toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Spark Plug > < Ignition Cable|Locations|Page 1536
Page 2
background image

If the resistance is greater than the maximum, check the terminals.
If necessary, replace the high-tension cord.

f.

Connect the high-tension cords to the ignition coils.
1. Assemble the holder and grommet.
2. Align the spline of the ignition coil with the spline of the holder, and push in the cord.

NOTE:  Check that the holder is correctly installed to the grommet and ignition coil as shown in the illustration.

3. Check that the lock claw of the holder is engaged by lightly pulling the holder.

g. Connect the high-tension cords to the spark plugs. Secure the high-tension cords with the clamps as shown in the illustration.
h. Install the intake air connector.
i.

Install the air cleaner cap and MAF meter assembly.

Spark Plug > < Ignition Cable|Locations|Page 1536