Hose/Line HVAC: Specifications

REFRIGERANT LINES

Receiver x Liquid tube:
 ..................................................................................................................................................................................................  6.0 N.m (61 kg.cm, 53 in.lb)

Condenser x Discharge tube:
 ....................................................................................................................................................................................................  10 N.m (100 kg.cm, 7 ft.lb)

Condenser x Liquid tube:
 ..................................................................................................................................................................................................  14 N.m (140 kg.cm, 10 ft.lb)

Compressor x Discharge tube:
 ....................................................................................................................................................................................................  10 N.m (100 kg.cm, 7 ft.lb)

Compressor x Suction tube:
 ....................................................................................................................................................................................................  10 N.m (100 kg.cm, 7 ft.lb)

Cooling unit x Liquid tube:
 ..................................................................................................................................................................................................  14 N.m (140 kg.cm, 10 ft.lb)

Cooling unit x Suction tube:
 ..................................................................................................................................................................................................  32 N.m (330 kg.cm, 24 ft.lb)

Expansion valve x Evaporator:
 ..................................................................................................................................................................................................  5.4 N.m (55 kg.cm, 48 in.lb)

Suction line:
 ..................................................................................................................................................................................................  32 N.m (330 kg.cm, 24 ft.lb)

Liquid line:
 ..................................................................................................................................................................................................  14 N.m (140 kg.cm, 10 ft.lb)