Tercel/Cor. Tercel L4-1452cc 1AC,3A,3AC (1984)
EFE Heater: Testing and Inspection
1.
Disconnect electrical connector to element and connect ohmmeter between element terminal and intake manifold.
2.
At 68°F, meter should indicate 0.35-1 ohm for ND type elements or 0.5-2 ohms for TDK type element.
3.
If resistance is not within specifications, heating element is defective.