Tercel Sedan 2-Door L4-1497cc 1.5L DOHC (5E-FE) (1995)
Radiator Cooling Fan Motor: Description and Operation
Service Hints
FAN RELAY
2-4-2-3:
Open with ignition SW ON, A/C single pressure SW ON and water temp. SW ON
A.C FAN NO.2 RELAY
2-5-2-4:
Closed with ignition SW OFF, A/C single pressure SW OFF or water temp. SW OFF
2-3-2-5:
Closed with ignition SW ON, A/C single pressure SW ON and water temp. SW ON
A.C FAN NO.3 RELAY
2-5-2-3:
Closed with ignition SW ON, and A/C magnetic clutch relay ON
HEATER RELAY
2-4-2-5:
Closed with ignition SW ON and blower SW ON
A11 A/C THERMISTOR
1-2:
Approx. 1500 Ohms at 25°C (77°F)
A 3 A/C DUAL PRESSURE SW
1-4:
Open with refrigerant pressure at less than Approx. 205.9 Kpa (2.1 Kgf/cm, 29.9 psi) or more than Approx. 2647.8 Kpa (27.0
Kgf/cm2, 384 psi)
A 3 A/C SINGLE PRESSURE SW
2-3:
Open with refrigerant pressure more than 1372.9 Kpa (14.0 Kgf/cm2, 199 psi)
E 4 ENGINE COOLANT TEMP.SW
1-Ground: Open above approx. 90° (194°F)
Closed below approx. 83°C, (181°F)