toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Conventional Starter|Page 1980 > < Conventional Starter
Page 1
background image

Starter Motor: Specifications
No Load Test and Brush Spring Tension, Reduction Type Starter

No Load Test and Brush Spring Tension, Reduction Type Starter 

Power Rating

1 kW 

   

  

  

 

Brush Spring Tension

62-85 oz 

   

  

  

 

No Load Test

Amperage

90 A 

   

  

  

 

Voltage

11.5 V 

    

  

  

 

  

  

 

Speed

3000 rpm 

    

  

  

 

  

  

 

Conventional Starter|Page 1980 > < Conventional Starter