Tundra 2WD V6-3.4L (5VZ-FE) (2004)
b. Using SST, press in the oil seal.
SST 09612-22011
NOTICE: Make sure to install the oil seal facing in the correct direction.
9. INSTALL CONTROL VALVE HOUSING WITH CONTROL VALVE ASSEMBLY
a. Place a new gasket on the rack housing.
b. Align the matchmarks on the control valve housing with control valve assembly and rack housing.
c. Install the 2 bolts.
Torque: 18 Nm (185 kgf-cm, 13 ft. lbs.)
10. INSTALL SELF-LOCKING NUT
Using SST to stop the control valve shaft rotating, install a new nut.
SST 09616-00011
Torque: 30 Nm (300 kgf-cm, 22 ft. lbs.)
11. INSTALL DUST COVER
12. INSTALL RACK HOUSING CAP
a. Apply sealant to 2 or 3 threads of the rack housing cap.
Sealant: Part No.08833-00080, THREE BOND 1344, LOCTITE 242 or equivalent
b. Using SST, install the rack housing cap.
SST 09816-30010
Torque: 59 Nm (600 kgf-cm, 43 ft. lbs.)
c. Using a punch and hammer, stake the 2 parts of the cap.