Ignition Cable: Testing and Inspection

INSPECT HIGH-TENSION CORDS

a. Remove the air cleaner cap and MAF meter assembly.
b. Disconnect the high-tension cords from the spark plugs. 

Disconnect the high-tension cords at the rubber boot.
Do not pull on the cords.

NOTE:  Pulling on or bending the cords may damage the conductor inside.

c. Disconnect the high-tension cords from the ignition coils.

1. Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.
2. Disconnect the high-tension cord at the grommet. 

Do not pull on the cord.

NOTE:  Pulling on or bending the cords may damage the conductor inside. Do not wipe any of the oil from the grommet after the high-tension
cord is disconnected.

d. Inspect the high-tension cord resistance.

Using an ohmmeter, measure the resistance.

Maximum resistance: 25 KOhm per cord

If the resistance is greater than maximum, check the terminals. 
If necessary, replace the high-tension cord.