7. DISCONNECT LIQUID TUBE AND DISCHARGE HOSE

Remove the 2 bolts and disconnect the both tube and hose.

Torque:  10 Nm (100 kg.cm, 7 ft.lb)

NOTE:  Cap open the fittings immediately to keep moisture or dirt out of the system.

HINT:  At the time of installation, please refer to the following item.
Lubricate 2 new O-rings with compressor oil and install them to the tubes.

8. REMOVE CONDENSER

a. Remove the 2 bolts and 2 lower brackets.
b. Remove the 4 bolts and 2 upper brackets.
c. Pull the condenser forward and pull it upward.

HINT:  At the time of installation, please refer to the following item.
If condenser is replaced, add compressor oil to the compressor.

Add 40 - 50 cc (1.4 - 1.7 fl.oz.) 

Compressor oil: ND-OIL 8 or equivalent

INSTALLATION

Installation is in the reverse order of removal.