Tundra Access Cab LTD 2WD V8-4.7L (2UZ-FE) (2000)
Hazard Warning Switch: Testing and Inspection
Turn Signal And Hazard Warning System
INSPECT HAZARD WARNING SWITCH CONTINUITY
a. Remove the center cluster finish panel.
b. Disconnect the connector from the center cluster integration.
c. Check that continuity exists between terminal 17 and terminal 1 with the switch ON.
d. Check that no continuity exists between terminal 17 and terminal 1 with the switch OFF
If continuity is not as specified, replace the switch.