toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Generator <--> [Alternator]|Removal and Installation|Page 3913 > < Generator <--> [Alternator]|Removal and Installation|Page 3911
Page 11
background image

f.

100 A type:
Place the voltage regulator and brush holder on the rectifier end frame.

NOTE:  Be careful of the brush holder installation direction.

g. 100 A type:

Install the 5 screws.

Torque: 1.96 Nm (20 kg.cm, 17 in.lb)

h. 100 A type:

Place the brush holder cover on the brush holder.

7. INSTALL REAR END COVER

a. 70 A type:

Install the end cover with the 3 nuts.

Torque: 4.4 Nm (46 kg.cm, 39 in.lb)

b. 100 A type:

Install the end cover and plate terminal with the bolt and 3 nuts.

Torque:
Bolt: 3.85 Nm (39 kg.cm, 34 in.lb)
Nut: 4.4 Nm (46 kg.cm, 39 in.lb)

Generator <--> [Alternator]|Removal and Installation|Page 3913 > < Generator <--> [Alternator]|Removal and Installation|Page 3911