Throttle Valve Solenoid: Description and Operation

The throttle pressure that is applied to the primary regulator valve (which modulates line pressure) causes the solenoid valve SLT, under electronic
control, to precisely and minutely modulate and generate line pressure according to the accelerator pedal effort, or the detected engine power output.
This reduces the function of line pressure and provides smooth shifting characteristics.
Upon receiving the throttle valve opening angle signal, ECM controls the line pressure by sending a predetermined (*) duty ratio to the solenoid valve,
modulating the line pressure, and generating throttle pressure.

(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of
non-continuity, then

Duty Ratio = A/A+B * 100 (%)