toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Power Window Switch|Testing and Inspection|Page 611 > < Power Window Switch|Testing and Inspection|Page 609
Page 3
background image

e. Check that the current increases up to approximately 14.5 A or more when the window stops going down.

HINT:  The circuit breaker opens some 4 - 40 seconds after the window stops going down, so that check must be done before the circuit brake
operates.

If the operation is not as specified, replace the switch.

INSPECT ONE-TOUCH POWER WINDOW SYSTEM/CURRENT OF CIRCUIT (Using an ammeter with a current-measuring probe)

a. Remove the master switch with connector connected.
b. Attach a current-measuring probe to terminal 9 of the wire harness.
c. Turn the ignition switch ON and set power window switch in the down position.
d. As the window goes down, check that the current flow is approximately 7 A.

e. Check that the current increases up to approximately 14.5 A or more when the window stops going down.

HINT:  The circuit breaker opens some 4 - 40 seconds after the window stops going down, so that check must be done before the circuit breaker
operates.

If operation is not as specified, replace the master switch.

Power Window Switch|Testing and Inspection|Page 611 > < Power Window Switch|Testing and Inspection|Page 609