Evaporator Case: Service and Repair
Removal And Installation

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT:  At the time of installation, please refer to the following item.

Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.

Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)

2. DISCONNECT LIQUID TUBE

5VZ-FE Shown

a. Using SST, remove the piping clamp.

SST 09870-00025 (Liquid tube)

1. Insert SST to piping clamp.

HINT:  Confirm the direction of the piping clamp claw and SST using the illustration showing on the caution label.

2. Push down SST and release the clamp lock.

NOTE:  Be careful not to deform the tubes, when pushing SST.

3. Pull SST slightly and push the release lever, then remove the piping clamp with SST.

Removal And Installation|Page 4691 > < Component Inspection|Page 4688