Tundra Regular Cab SR5 4WD V8-4.7L (2UZ-FE) (2000)
b. Using an ohmmeter, measure the resistance between terminals +B and HT.
Resistance:
At 20 °C (68 °F)
11 - 16 Ohms
At 800 °C (1,472 °F)
23 - 32 Ohms
If the resistance is not as specified, replace the sensor.
Torque:
44 Nm (450 kg.cm, 32 ft.lb) for sensor 1
20 Nm (200 kg.cm, 14 ft.lb) for sensor 2
c. Reconnect the oxygen sensor connector.
2. INSPECT OPERATION OF HEATED OXYGEN SENSORS