Venza FWD L4-2.7L (1AR-FE) (2009)
(c) Check for air leaks.
(1) Remove the air hose between ports A and B.
(2) Connect a pressure gauge to the vent port of the charcoal canister.
Text in Illustration
(3) While holding port B, with the purge port and the air inlet port closed and port A open, apply 19.6 kPa (0.2 kgf/cm2, 2.81 psi) of
pressurized air into the vent port, then confirm that pressure is retained for 1 minute.
If the result is not as specified, replace the charcoal canister.
(d) Check the leak detection pump.
(1) Remove the canister pump module.
(2) Check that air flows from port A to port B and C.
Text in Illustration
If the result is not as specified, replace the charcoal canister.