Operational procedure
|
Paint stage
|
Products
|
Notes
|
|
I
|
II
|
III
|
|
|
Clean
|
x
|
x
|
x
|
Antistatic cleaner
|
Spray on using pump atomiser and dry with highly absorbent
cloth.
|
Sand
|
x
|
x
|
x
|
Wet sandpaper
|
Sand down fault site with grain no lower than P 800. Give a matt
finish to remaining surface using sanding/matting pad fine, blend
prep.
|
Prime
|
–
|
x
|
x
|
Plastic primer
|
Spray two layers. Setting time 5 minutes. Paint stage II
includes minor repairs (no putty application).
|
Sand
|
–
|
x
|
x
|
Sanding/matting pad fine
|
After drying, only if required.
|
Clean
|
x
|
x
|
x
|
Tack cloth
|
Remove dust (paint mist).
|
Spray base paint
|
x
|
x
|
x
|
Top-2-coat metallic base coat
|
Spray one layer. Setting time 3 minutes. Final spraying with two
more layers. Setting time 15 minutes prior to clear coat
application.
|
Elasticate clear coat
|
x
|
x
|
x
|
2-C-Acrylic clear coat - plastocryl 2-C-HS clear coat
|
Elasticate clear coat. 100 parts – clear coat 20 parts
– plastocryl
|
Spray clear coat
|
x
|
x
|
x
|
Elasticated clear coat 2-C-MS hardener
|
100 parts of elasticated clear coat, 50 parts of hardener, 10
parts thinner.
|
|
|
|
|
Elasticated 2-C-HS clear coat, 2-C-MS hardener
|
100 parts of elasticated HS clear coat - new, 60 parts of
hardener, plus max. 10% thinner.
|
|
|
|
|
Universal thinner
|
Spray one layer. Setting time 3 to 5 minutes. Final spraying
with one more layer. Setting time 8 minutes prior to oven
drying.
|