Table 2, F2:TROUBLE CODE TABLE
Trouble Code
Information Sensor Cause of Fault
Remedy in F0:DATA LIST No.
Trouble Code Storage when ...
Remarks
31
SQUIB DRIVER
OPEN CIRCUIT
02
· Resistance of squib circuit 1 is greater than
5 W (circuit interruption)
· Above condition must be fulfilled for 3 to 5 s
If trouble code 31 was recognized, the airbag telltale is switched on.