Pressures for Brake Proportioning Valve - Check for Saloon and Convertible (as of MY '95)
Engine version or model
Ident. No. for Lead and Switch-over pressure at Valve Housing
Input overpressure, read off manometer on front axle in kPa (bar)
Output overpressure, read off manometer on rear axle in kPa (bar)
16 LZ2
3/2.5
500 (5)
6000 (60)
3550 ± 200
(35,5 ± 2)
10000 (100)
4750 ± 300
(47,5 ± 3)
X 16 XEL
3/38-85
4460 ± 200
(44,6 ± 2)
5660 ± 300
(56,6 ± 3)
X 20 XEV
3/2.0-7.0
3200 ± 200
(32 ± 2)
4400 ± 300
(44 ± 3)