Table 2, TROUBLE CODE TABLE

 

 

Trouble Code

Information Sensor Cause of Fault

Remedy in F0:DATA LIST No.

Trouble Code Storage when

21

THROTTLE POSIT. SENSOR VOLTAGE HIGH

 

03

·   The control unit recognizes a voltage > 4.9 V at the "potentiometer nominal value" input (short circuit to battery or lead interruption).

 

·   The fault is stored after maximum 1 s.

 

Note:     A short circuit of the positive potentiometer voltage supply to the battery voltage leads to the safety relay being switched off without the trouble code being stored.

 

On fault recognition, the ETC function is switched off and the ETC telltale is activated.

 

 

 

 