vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Table 2, Trouble Code Table - TC 82 ETC ON/OFF SW. VOLTAGE LOW > < Table 2, Trouble Code Table - TC 63 ETC-THR. MOTOR OPEN CIRCUIT

Table 2, TROUBLE CODE TABLE

 

 

Trouble Code

Information Sensor Cause of Fault

Remedy in F0:DATA LIST No.

Trouble Code Storage when

64

ETC-THR. MOTOR SHORT CIRCUIT

 

 

Actuator Test No. 01

·   Short circuit to ground or battery voltage in final stage, outside of control unit in ETC servo motor or in its leads.

 

·   The fault is stored after maximum approx. 1 s.

 

On fault recognition, the procedure is as follows:

 

With a short circuit to ground, the final stage transistors switching to positive are deactivated; with a short circuit to battery voltage, the final stage transistors switching to ground are deactivated. If the short circuit signal remains active although the final stages are switched off, the safety relay is then switched off. The ETC system is switched off and the ETC telltale is activated.

 

 

 

 


Related Literature Units
-F5:ACTUATOR TEST No. 01 SELECT ACTUATOR ETC-THR. MOTOR

Table 2, Trouble Code Table - TC 82 ETC ON/OFF SW. VOLTAGE LOW > < Table 2, Trouble Code Table - TC 63 ETC-THR. MOTOR OPEN CIRCUIT