F0: DATA LIST
No.
TECH 1 Display
Conditions for Checking
Nominal Value
Trouble Codes
Terminal
25
IGN. COIL
TER. 1
Ignition ON
Engine running at idle speed
CHARGE
Fast change between CHARGE
and IGNITE
-
1/24
Notes for Trouble-shooting:
Nominal Value:
Cause of Fault:
· Inition ON
· Measure voltage at
- Control unit Ter. 27
- Ignition coil Ter. 1
- Ignition coil Ter. 15
11.5 to 13.5 V
· Lead interruption from control unit Ter. 27 or from Ter. 15 to ignition coil
· Connect primary signal with adapter and TECH 80 to ignition coil Ter. 1 and start engine
300 to 400 V
· Interruption or short circuit to ground of lead
- Ignition coil Ter. 1 to control unit Ter. 1
- Ignition coil Ter. 1 to tachometer
· Control unit defective
· Ignition coil defective
Nominal values are attained
Resistance of ignition coil at room temperature: primary side: approx. 0.5 W
secondary side: approx. 7 kW