Motronic M 2.8 Quick Check F0:DATA LIST
No.
TECH 1 Display
Conditions for Checking
Nominal Value
Trouble Codes
Ter-
minal
40
O2 BLM PART THR.
Engine running at idle speed, operating temperature
C 20 XE engine:
C 25 XE engine:
118 to 138 steps
118 to 142 steps
13, 38, 39
-