Test
|
Test Equipment
|
|
|
|
Nominal
|
Possible Cause of
Fault,
|
Step
No.
|
Multimeter
MKM - 587 - A
|
Test of
|
Terminal
|
Notes
|
Values
|
Trouble-shooting
|
|
|
|
|
|
|
|
1
|
Ohmmeter
|
Diagnostic
|
A/ground
|
Ignition OFF
|
approx. 0 W
|
· Transfer
resistance at
|
|
|
plug (ALDL):
|
|
|
|
grounding point too high
|
|
|
ground
|
|
|
|
|
|
|
|
|
|
|
|
2
|
Voltmeter
|
Diagnostic
|
B/ground
|
Ignition ON
|
greater
|
· Lead interruption
between
|
|
range: 20 V
|
plug (ALDL):
|
|
|
than 11.5 V
|
X 13 / Ter. B or X 11 / Ter. 4
|
|
DC
|
excitation
|
|
|
|
and K 61 / Ter. 13
|
|
|
lead
|
|
|
|
· Control unit
K 61 defective
|
|
|
|
|
|
|
|
3
|
Voltmeter
|
Diagnostic
|
F/ground
|
Ignition ON
|
greater
|
· Battery voltage
too low
|
|
range: 20 V
|
plug (ALDL):
|
|
|
than 11.5 V
|
· Lead interruption
between
|
|
DC
|
voltage
|
|
|
|
X 13 / Ter. F and voltage
|
|
|
supply
|
|
|
|
supply
|
|
|
|
|
|
|
· Astra-F:
|
|
|
|
|
|
|
Fuse F 7 defective
|
|
|
|
|
|
|
· Vectra /
Cavalier / Calibra:
|
|
|
|
|
|
|
Fuse F 2 defective
|
4
|
Voltmeter
|
Diagnostic
|
G/ground
|
Ignition ON
|
greater
|
· Lead interruption
between
|
|
range: 20 V
|
plug (ALDL):
|
|
|
than 9 V
|
X 13 / Ter. G or
|
|
DC
|
data lead
|
|
|
|
X 11 / Ter. 5 and
|
|
|
|
|
|
|
K 61 / Ter. 55
|
|
|
|
|
|
|
· Control unit
K 61 defective
|
5
|
-
|
Telltale H 30
|
-
|
Ignition ON
|
Telltale ON
|
· Telltale H 30
defective
|
|
|
(ALDL):
|
|
|
|
· Astra-F:
|
|
|
ground
|
|
|
|
Fuse F 7 defective
|
|
|
|
|
|
|
· Vectra /
Cavalier / Calibra:
|
|
|
|
|
|
|
Fuse F 2 defective
|
|
|
|
|
|
|
· Lead interruption
between
|
|
|
|
|
|
|
H 30 and K 61 / Ter. 22
|
|
|
|
|
|
|
· Control unit
K 61 defective
|
6
|
-
|
TECH 1
|
-
|
See
|
-
|
-
|
|
|
self-test
|
|
TECH 1
|
|
|
|
|
|
|
Operating
|
|
|
|
|
|
|
Instructions
|
|
|
Note: After
test steps 7 and 8, any stored trouble codes are deleted.
|
|
7
|
Ohmmeter
|
Control unit
|
Ter. 14/
|
Ignition OFF
|
approx. 0 W
|
· Transfer
resistance at
|
|
|
plugK 61:
|
ground
|
Disconnect
|
|
grounding point too high
|
|
|
ground
|
Ter. 1 9/
|
plug from
|
|
· Lead interruption
between
|
|
|
|
ground
|
control unit
|
|
K 61 and grounding point
|
|
|
|
Ter. 24/
|
K 61
|
|
· Control unit
K 61 defective
|
|
|
|
ground
|
|
|
|
8
|
Voltmeter
|
Control unit
|
Ter. 18/
|
Ignition OFF
|
> 11.5 V
|
· Battery voltage
too low
|
|
range: 20 V
|
plug K 61:
|
ground
|
Disconnnect
|
|
· Lead
interruption between Ter.30
|
|
DC
|
voltage supply
|
Ter. 27/
|
plug K 61
|
|
or Ter. 15 and control unit
K 61
|
|
|
Ter. 30
|
ground
|
Ignition ON
|
|
· Control unit
K 61 defective
|
|
|
and Ter. 15
|
|
|
|
· Fuel pump relay
K 68 defective
|
|
|
|
|
|
|
|
|