Affected terminals: F10,
or A10, or B2
Possible trouble codes: 83,
84, 85
Note:
This mode can be used to program
the engine control unit's imo signal. This is necessary when a new control
unit is installed in a vehicle or when a new immobiliser control unit is
installed and the engine control unit has to "learn" the new imo
signal from the immobiliser control unit.
Press key F7 in the system main
menu, use the arrow keys to select the desired test and confirm with YES.
Follow the instructions in the TECH 1 display.
Ignition OFF
Wait for 12 seconds
Note:
Before the ignition is switched
on, a waiting period of at least 12 seconds must have elapsed since the last
time the ignition was switched off, as otherwise the engine control unit does
not send a new request to the immobiliser control unit for the imo signal
(control unit run-on period).
|