Multec M (14 SE / C 14 SE / C 16 SE) Quick Check F0:DATA LIST
No.
TECH 1 Display
Conditions for Checking
Nominal Value
Trouble Codes
Ter-
minal
14
ENGINE SPEED
Engine running at idle speed, operating temperature
Astra-F
Corsa-A, Corsa-B, Nova
820 to 980 rpm
850 to 1010 rpm
19,35
A 2 / B 3