· Ignition OFF
· Disconnect wiring harness
plug X 8 / X 4
· Bridge X 8:
from: X 8 Ter. 4 / X4 Ter. 2 (at the control unit side)
to: battery voltage Ter. 30
· Ignition ON
|
ACTIVE 12V
|
· Lead interruption
from: control unit plug K 57/K 91 Ter. D 6
to: plug X 8 Ter. 4 / X 4 Ter. 2
· Control unit defective
|
· Ignition OFF
· Connect wiring harness
plug X 8
· Bridge plug at switch S
109
(AC load, speed increase)
from: S 109 Ter. 1
to: S 109 Ter. 2
· Ignition ON
· AC switch ON
|
|
· Lead interruption
from: S 109 Ter. 2
to: plug X 7 Ter. F
or
from: plug X 7 Ter. F
to: plug X 8 Ter. 4
· Short circuit in the
wiring harness
from: S 109
to: ground
|
· Ignition OFF
· Connect wiring harness
plug X 4
· Bridge plug at switch S
109
(AC load, speed increase)
from: S 109 Ter. 1
to: S 109 Ter. 2
· Ignition ON
· AC switch ON
|
ACTIVE 12V
Fan operating
|
· Fuse F 21 defective
· Lead interruption
from: fuse F 21
to: wiring harness plug X 6 Ter. 61
or
from: wiring harness plug X 6 Ter. 61
to: switch S 109
or
from: switch S 109
to: wiring harness plug X 6 Ter. 58
· Short circuit in wiring
harness
from: switch S 109
to: ground
|