Multec-S X 14 XE
/ X 16 XE (L) F0:DATA LIST
No.
|
TECH 1 Display
|
Conditions for
Checking
|
Nominal Value
|
Trouble Codes
|
Terminal
|
34
|
ENGINE
SPEED
|
Ignition ON
Engine running at idle speed, operating temperature
|
0 rpm
|
35, 19
|
B14 / A16
|
|
|
X 14 XE MT:
|
850 to 950 rpm
|
|
|
|
|
X 16 XE MT:
|
825 to 975 rpm
|
|
|
|
|
X 16 XEL MT:
|
700 to 1000 rpm
|
|
|
|
|
X 14 XE AT:
Selector lever position
"P"
|
850 to 950 rpm
|
|
|
|
|
X 14 XE AT:
Selector lever position
"D"
|
725 to 825 rpm
|
|
|
|
|
|
|
|
|