Note:
In this control mode,
TECH 1 specifies an idle speed to the control unit which it has to
maintain.
The engine speed can be set to a
fixed value using the arrow keys. In addition, the YES and NO keys can be
used to display the various data list parameters. Using key F9, it is
possible to store data as in the snapshot mode.
This mode should be used if it
appears necessary to evaluate the various engine parameters (e.g. O2 INTEGRATOR or INJECTION PULSE)
at fixed/ increased idle speeds, or for checking whether the idle speed
adjuster operates smoothly and without sticking over the entire opening
range.
|