F0:Data List Test Step 36 DES. IDLE ADJUST > < Idle speed stepper motor remove and install

Multec- S X 14 XE /  X 16 XE (L)      F0:DATA LIST

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

35

DESIRED IDLE

Ignition ON

Engine running at idle speed, operating temperature

Nominal idle speed has not been changed (basic setting after control unit reset)

 

 

-

 

 

X 14 XE / X 16 XE MT:

900 rpm

 

 

 

 

X 16 XEL MT:

850 rpm

 

 

 

 

X 14 XE AT:

            selector lever position "P"

900 rpm

 

 

 

 

X 14 XE AT:

            selector lever position "D"

775 rpm

 

 

 

 

Nominal idle speed has been programmed:

 

 

 

 

 

X 14 XE:

850 to 950 rpm,

except 900 rpm

 

 

 

 

 

X 16 XE:

 

825 to 975 rpm,

except 900 rpm

 

 

 

 

 

X 16 XEL:

 

700 to 1000 rpm,

except 850 rpm

 

 

 

 

 

X 14 XE AT:

            selector lever position "P"

 

850 to 950 rpm,

except 900 rpm

 

 

 

 

X 14 XE AT:

            selector lever position "D"

 

725 to 825 rpm, except 775 rpm

 

 

 

 

Note:

In vehicles with automatic transmission, different values are indicated depending on the selector lever position.

 

 

 

 

 

 

 

 

 

Note:

DESIRED IDLE indicates the nominal idle speed depending on the engine / transmission combination and the operating conditions; e.g. the nominal idle speed is higher in the warm- up phase.

DESIRED IDLE is an internal value of the control unit and cannot be diagnosed.

 

Notes on Trouble-shooting:

Nominal Value:

Cause of fault:

(If nominal value is not attained)

 

·   Check following nominal values:

·   TECH 1 data list no. 32 O2 BLM CELL NO.

 

OK

 

·   Remedy according to data list no. 32 O2 BLM CELL NO.

 

·   Check control unit calibration, see field remedy measures

 

Latest program memory (EPROM) according to field remedy measures or TIs

 

·   Replace program memory (EPROM) according to field remedy measures or TIs

 

 

If nominal values are attained and latest program memory is installed

·   K57 engine control unit defective

 

 

 

 

 

 

 

 