Remove oxygen sensor only with engine at operating temperature.
Remove, Disconnect Disconnect wiring harness plug (1) from oxygen sensor. Unscrew oxygen sensor from exhaust manifold.
Important! When reusing the oxygen sensor smear its thread with special grease (black). Ensure correct routing of cable - route cable of the oxygen sensor so that abrasion does not occur and it cannot come in contact with the exhaust pipe.
Install, Connect Screw oxygen sensor into exhaust manifold - tightening torque 30 Nm. Connect oxygen sensor to wiring harness plug. |