Detach air intake hose or air intake pipe (1) from upper part of air cleaner housing. Unclip retaining clips (2) from upper part of air cleaner housing - remove upper part of air cleaner housing. Loosen fastening nuts of lower part of air cleaner housing and remove lower part of air cleaner housing with air duct hose.
Install, Connect Insert lower part of air cleaner housing with air duct hose and tighten fastening nuts. Clip upper part of air cleaner housing to lower part of air cleaner housing with retaining clips. Attach air intake hose or air intake pipe to upper part of air cleaner housing. |