Multec (X 12 SZ / X 16 SZ) F0: DATA LIST
No.
TECH 1 Display
Conditions for Checking
Nominal Value
Trouble Codes
Terminal
36
DIAG. REQUEST
Ignition ON
INACTIVE
12V
-
D 8 / D 1
Trouble - shooting:
Nominal Value:
Cause of Fault:
(If nominal value is not attained)
· Ignition OFF
· Measure voltage:
from: diagnostic plug Ter. "B"
to: ground
· Ignition ON
INACTIVE 12V
greater than 11 V
· Short circuit in wiring harness
from: diagnostic excitation lead "B" in diagnostic plug
· Carry out check according to table 1.