TECH 1 display constantly less than or equal to
0.17 V:
· Short
circuit to ground or lead interruption from control unit Ter. 27 to mass air
flow meter Ter. 2
· Short
circuit of signal lead for mass air flow meter Ter. 2 / control
unit Ter. 27 to ground lead for mass air flow meter Ter. 4 / control
unit Ter. 8
· Mass
air flow meter P44 defective
TECH 1 display constantly greater than or equal to
4.5 V:
· Astra -
F, Vectra / Cavalier, Calibre:
Short circuit of signal
lead for mass air flow meter Ter. 2 / control unit Ter. 27 to lead for
mass air flow meter Ter. 3 / fuel pump relay Ter. 8 (Ter. 87),
+ battery voltage
Omega - B:
Short circuit of signal
lead for mass air flow meter Ter. 2 / control unit Ter. 27 to lead for
mass air flow meter Ter. 3 / reverse battery protection relay K42 /
Ter. 8 (Ter. 87), + battery voltage
· Mass
air flow meter P44 defective
· Control
unit K69 defective
|