Disconnect wiring harness plug (2) from hot film mass air flow meter. Loosen hose clamps (1) and remove hot film mass air flow meter from air intake hoses. In the event of external damage (e.g. deformation of grid), replace hot film mass air flow meter.
Install, Connect Insert hot film mass air flow meter in air intake hoses - ensure hose conditions are in good condition and correctly seated. Air intake hose must engage in recesses (arrows) in hot film mass air flow meter. Tighten hose clamps (1). Connect wiring harness plug (2) to hot film mass air flow meter. |