FO: DATA LIST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

12

A /C COMPRESS. SW

Ignition On

 

Engine running at idle speed, operating temperature

Ambient temperature higher than 20 °C / 68 °F

 

Vehicles with AC:

AC switch On

 

Vehicles without AC:

 

INACTIVE

                   0 V

 

INACTIVE

                   0 V

 

ACTIVE

                   12 V

 

INACTIVE

                   0 V

 

12, 19

 

Note:   The lead to Ter. 12 in control unit K69 is present in all vehicles but is open on the vehicle side in vehicles without AC.

              Vehicle interior should be warm, set thermostat to "Cold", ventilation to full load; compressor switches on automatically

              In some vehicles, it is necessary to accelerate briefly or to wait while until the compressor has built up pressure and switches.

 

Notes on Trouble - shooting:

Nominal Value:

Cause of Fault:

 

Vehicles without AC:

 

·     Using multimeter, measure voltage at wiring harness plug

       - X8 / Ter. 4           (Astra - F)

       - X11 / Ter. 3         (Vectra / Cavalier, Calibre)

       - X30 / Ter. 2         (Omega - B)

       to ground,

       Ignition On.

 

Vehicles with AC:

 

 

 

0 V

 

 

·     Short circuit to + battery voltage

 

·     Engine running at idle speed, operating temperature.

       Using multimeter, measure voltage at wiring harness plug

       X8 / Ter. 4             (Astra - F)

       X9 / Ter. 3             (Vectra / Cavalier, Calibra)

       X30 / Ter. 2           (Omega - B)

       to ground,

 

 

 

 

       AC Off

 

 

 

 

       AC On

       (observe note)

0 V

 

 

 

 

12 V

Compressor switches on

·     Fault in AC switch - on circuit

·     Lead has short circuit to + battery voltage

 

·     Fault in AC switch - on circuit

·     Short circuit to ground or interruption in lead from control unit K69 / Ter. 12 via wiring harness plug

       - X8                        (Astra - F)

       - X9                        (Vectra / Cavalier, Calibre)

       - X30                      (Omega - B)

       to compressor switch S109

 

 

 

 