F5: ACTUATOR TEST - No. 01 SELECT ACTUATOR IGN. COIL CYL1+4 > < DIS ignition module, remove and install

FO: DATA LIST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

33

SPARK ADVANCE

Engine running at idle speed, operating temperature

Switch off all consumers

Astra - F

Omega - B

Vectra / Cavalier, Calibra

 

 

 

 

6 to 14 °CA

5 to 14 °CA

2 to 8 °CA

-

-

 

Note:    The firing angle is a value calculated by the control unit and is influenced by various other parameters

              (e. g. coolant temperature, intake air temperature, idle speed stabilizing).

              The firing angle cannot be adjusted by the mechanic.

           The nominal value range for the above test conditions applies at a normal ambient temperature of approx. 20 °C / 68 °F

              (intake air temperature lower than 40 °C / 104 °F). If there are deviations in the temperature or if the engine has been running at idle speed for an extended period of time, the firing angle may move in the range

              - 2 to 14 °CA (Astra - F)

              - 5 to 16 °CA (Omega - B)

              - 0 to 10 °CA (Vectra / Cavalier, Calibre).

 

Notes on Trouble - shooting:

Nominal Value:

Cause of Fault:

 

·     Check crankshaft /camshaft pulse pick - up (see FO: DATA LIST, test step 22)

 

 

 

 

 

 

F5: ACTUATOR TEST - No. 01 SELECT ACTUATOR IGN. COIL CYL1+4 > < DIS ignition module, remove and install