Remove crankshaft bearing cap. Attach Dial Gauge MKM-571-B with dial gauge bracket to cylinder block. Attach probe of the Dial Gauge MKM-571-B to crankshaft bearing journal.
Measure Turn crankshaft smoothly. Maximum out-of-round: 0.03 mm.
Install, Connect Remove holder with Dial Gauge MKM-571-B. Install crankshaft bearing cap with new bolts to cylinder block - tightening torque 50 Nm/37 lbf. ft. + 45 ° +15 ° . |