Trouble Code
|
Information
Sensor Cause of Fault
|
Remedy in F0:DATA LIST No.
|
Trouble Code Storage when ...
|
75
|
TORQUE CONTROL VOLTAGE LOW
|
26
|
· The voltage level
recognized by transmission control unit at the relevant control unit output
(Ter. 13) is Low (less than 2.5 V), although control unit output was set at
High (greater than 4 V, pull-up resistor in Motronic control unit)
(short circuit to ground, Ter. 31)
If trouble
code 75 was recognized, shifting can still be made manually (emergency
program) to the following gears at the individual driving speeds:
Automatic
Transmission AF 14/20:
"Driving
stage" (gear): "D" (4), "3" (3), "2" (3),
"1" (1)
Automatic
Transmission AF 13/22:
"Driving
stage" (gear): "D" (4), "3" (4), "2" (3),
"1" (1)
|