Seal Rings for Check Bore (Fluid pressure), Replace
Remove, Disconnect
Affected plug - fluid escapes. Replace seal ring.
Tighten (Torque)
AF 20 = 10 plugs:
Plug SW 13 (1) to transmission
- 8 Nm/6 lbf. ft.
Plug M 14 (2) to transmission
- 35 Nm/26 lbf. ft.
Plug M 18 (3) to transmission
Plug M 20 (4) to transmission
AF 13 = 12 plugs:
Plug size 13 to transmission - 8 Nm/6 lbf. ft.