vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Quick Check F5:Actuator Test SEC. AIR P.REL > < F2:Trouble Codes - Trouble Code No. 57 AIR CONTROL SOL. VOLTAGE HIGH

Multec- S X 14 XE / X 16 XE(L)        Quick Check F5:ACTUATOR TEST

 

AIR CONTR. SOL

 

Conditions for Checking

Nominal Value

Affected terminals:                   A11

Possible trouble codes:             56, 57

 

Disconnect wiring harness plug from:

34 tank vent solenoid valve

 

 

Ignition ON

Engine OFF

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.

 

Note:

The secondary air injection solenoid valve is actuated constantly.

The check is completed after a maximum of 10 s.

changes from

INACTIVE

to

ACTIVE

 

Noise check:

click from secondary air injection solenoid valve

 

 

Notes on Trouble-shooting:

Nominal Value:

Cause of fault:

(If nominal value is not attained)

 

·   Remedy according to data list no. 23 AIR CONTROL SOL.

 

 

 

 

 

 

 

 

 

Quick Check F5:Actuator Test SEC. AIR P.REL > < F2:Trouble Codes - Trouble Code No. 57 AIR CONTROL SOL. VOLTAGE HIGH